Restoration of lesions by stitching and injections
The restoration of lesions in reinforced concrete structures is achieved by injecting epoxy resin, after drilling holes across the lesion, with a pitch of between 15 and 25 cm. The injectors must be blocked with a two-component thixotropic epoxy adhesive and the surface filling of the lesion must be carried out using the same product.
Features
- Extremely wetting fluid resin
- Low viscosity
Technical Documentation
Operational Phases
- Preparation of the support
- Drilling the holes
- Injecting the resin